NOV (National Oilwell Vacro) is a global company in the fields of drilling and conveying technology. NOV supports the world’s most advanced drilling solutions in the oil and gas industry.
Here almost 150 measuring channels are used in a test system:
- 10 x IEPE with 5 x Q.bloxx A101
- 24 x current with 3 x Q.bloxx A108
- 12 x Pt100 with 3 x Q.bloxx A107
- 96 x SG with 12 x Q.bloxx A116
- Multiple digital I/Os
The measured data is recorded at a sample rate of 10 kHz. A data logger was configured in the Q.station test controller that records the conditioned and raw data. The recorded data is transferred to a SQL database using the test.node server software.
At present, four test systems are being built; with additional systems being planned. Testing is performed in cooperation with our Danish partner IPC Teknik ApS.
More articles
Introducing the Q.series X A12x 1500V Plus Versions
Gantner Instruments expanded the A12x module lineup with Plus versions (e.g., Q.series X A128 Plus SEB) that feature an increase in their voltage capacity up to 1500V, meeting the evolving demands of industries that require higher voltage limits for testing and measurement. Let's delve deeper into the enhanced capabilities of the A12x module lineup and how they empower engineers across various industries.
Read more...Q.series demo at European Rotorcraft Forum
From September 5 – 8, Gantner participated in the 42nd edition of the European Rotorcraft Forum. The event was held in Lille, France.
Read more...Changing demands within Automotive Testing – Webinar
Want to know more about changing demands within Automotive Testing?
Read more...High-Accuracy, EHV Battery Temperature Measurement DAQ: GM Application Note
Gantner Universal Test & Measurement DAQ Systems with Precise Temperature Measurement, Distributed I/O, and Signal Conditioning, Selected for GM (Chevy Volt) Battery Testing.
Read more...