Austria | Germany | France | Sweden | India | USA | China | Singapore
How to enhance your EtherCAT master with best real-time DAQ
Tips & Trends | 3 minutes Reading Time |

How to enhance your EtherCAT master with best real-time DAQ

Connectivity and flexible integration of our high-accuracy and high-speed I/O modules into any automation system is in our DNA. Therefore you are now able to integrate our high-performance Q.series X I/O modules into all industry standard EtherCAT masters like TwinCat, Koenig KPA, NI VeriStand, and Acontis.

EtherCAT was developed with industrial automation in mind, so finding EtherCAT-ready high-accuracy data acquisition devices which cover a wide range of sensors can be a challenge. Modern data acquisition system vendors such as Gantner Instruments offer a full range of measurement modules with a direct EtherCAT interface. There is no limitation in the type of sensors you can use within an EtherCAT-based data acquisition system: thermocouple, Pt100, LVDT, strain gage, IEPE/ICP©, piezoelectric (charge), high-voltage measurement up to 1200 VDC, and even fiber Bragg grating sensors.

Gantner Instruments provides you with robust I/O modules with the best-in-class accuracy, high stability, and minimal noise without long-term drift for all of the measurement types mentioned above. What do we mean by best-in-class accuracy?

Here are three examples: 

  • The margin of error for our A105 I/O module with four channels for RTD measurements is 0.05 K at a resolution of 100 µK.
  • Our A108 I/O module brings eight channels of voltage or current measurements with an error margin of +/-2 mV for an input range of +/-10 V with a resolution of 1.5 µV.
  • Our A116 I/O module can support eight inputs of quarter-, half-, and full-bridge strain-gages with an accuracy as low as 0.05 %.
Open the Product Finder

The Q.series X line of I/O modules is equpipped with pre-engineered signal conditioning functionality out-of-the-box. There is no need to program filters, linearization curves, or sensor scaling functions. With Gantner’s configuration software GI.bench, all configuration is done by mouse click, and also arithmetic functions like RMS, min., max., and average are set without any programming necessary. Suppose you choose a module that includes digital outputs. In that case, you can trigger an alarm output independent from any interaction with the master stack by defining a threshold directly on the I/O module.

Benefits in using our DAQ Platform

Benefits
  • Pre-engineered data acquisition functionality 
  • Out-of-the-box signal conditioning
  • 20 continuous and triggered data loggers
  • Significantly higher data rates
  • Arithmetic, linearization and scaling functions
  • No Sensor limitation
  • Filtering onboard
  • Alarm triggering
  • 3-way 500 VDC galvanic isolation 


Our Q.series X are in stock and we are able to deliver very fast.
Don’t miss this Chance and request a quote now!

Click to request a quote

Why Gantner Instruments DAQ modules make your life easier?

All Gantner Instruments I/O modules are fully compliant with the EtherCAT slave specifications from the EtherCAT Technology Group (ETG). Our I/O modules can connect with any EtherCAT master stack that follows these ETG specifications. To make integration with your master stack as simple as ABC, we provide various options for setting up our I/O modules in your EtherCAT master:

  • EtherCAT Slave Information (ESI) file: With our GI.bench DAQ software, you can configure the I/O modules then easily export ESI files, which is the XML file used by many EtherCAT masters to configure slave devices and generate network description files.
  • CoE online scan: The dynamic exchange of configuration settings between slave modules and the EtherCAT master using CAN Application Protocol over EtherCAT (CoE). This feature is supported by more advanced EtherCAT masters and offers extended flexibility between various hardware platforms all using EtherCAT. 
  • Direct EtherCAT master interface: Our GI.bench software offers the unique capability to interface with several EtherCAT master stacks to configure I/O modules directly via File Access over EtherCAT (FoE). This outstanding functionality is available for TwinCAT, the EC Master stack from Acontis, and the KPA master from koenig-pa GmbH.
GI.bench supports easy configuration for multiple EtherCAT masters

Learn how Fraunhofer is using our DAQ platform in combination with TwinCAT

Discover how Fraunhofer Institute of Wind Energy Systems (IWES) aims to reduce the development costs and yield losses associated with operating 10+ MW wind turbines and why they chose Gantner Instruments DAQ for the job.

Download case study

Is your EtherCAT master not listed here? Contact us to discuss the use of our DAQ hardware with your EtherCAT master stack!

More articles

Products & Services

Q.series X A192

The Multifunction Module when Flexibility and the Highest Performance Matters Most

Read more...
News & Events

Automation and Testing 2024

Bridging Ideas with Reality in Industry 4.0 14-16 February 2024 | OVAL Lingotto Fiere, Torino, Booth C18