Austria | Germany | France | Sweden | India | USA | China | Singapore
Gantner Instruments presents cryogenic measurement solution at Space Tech Expo
News & Events | 2 minutes Reading Time |

Gantner Instruments presents cryogenic measurement solution at Space Tech Expo

From October 24 -26 the Space Tech Expo and Conference took place in Bremen, Germany. The Space Tech is Europe’s meeting place for space business, Technology and innovation.

During the three-day trade fair Stephan Ploegman, Business Development Manager Aerospace, talked about our measurement solution for low temperature and strain measurement for space simulation testing.


Satellites are expensive and complex systems consisting of different subsystems and components. Extreme temperatures can cause expansion or contraction of satellite components. This can induce micro-vibrations or even stress fractures in the satellite structure. Once placed into orbit the it cannot be repaired. Therefore, a satellite is tested thoroughly before it is launched into space. During space simulation testing, satellites are exposed to the extreme temperatures of space for several weeks. Conditions for testing are stringent and the tests must correlate as close as possible to the real space conditions. Accurate measurement of temperature and strain at these extreme conditions is a major challenge.

Our A105 CR measurement module has been designed for use with cryogenic temperature sensors, like Cernox® or TVO. To minimize sensor self-heating, which will result in a measurement error, the module provides a sensor excitation as low as 7.5 µA whilst maintaining a good SNR. Furthermore, the module comes with a sensor specific linearization table using up to 32 calibration points to compensate for the high non-linearity of cryogenic temperature sensors.
A variant of our renowned A101 module has been introduced for measuring strain in a low temperature environment according to accuracy class 0.05%. The module comes with smart ON/OFF switching of the bridge excitation voltage to avoid sensor self-heating and microphonics (when used in a magnetic environment). Also, the module features a 3-step measurement to correct for the influence of thermoelectric voltage when using special cryogenic wiring. For more information, please contact your local Gantner Instruments representative.

More articles

News & Events

AUTO TECH China 2023

The 10th China Guangzhou Automotive Test Expo, held within AUTO TECH 2023, is South China’s largest automotive test, evaluation, and quality engineering exhibition. It gathers full vehicle and component testing and validation technologies and services!

Read more...
News & Events

Automotive Testing Expo Europe 2024

Get ready to revolutionize your automotive testing game with Gantner Instruments at the Automotive Testing Expo Europa 2024 in Stuttgart, Germany! From June 4 to 6, visit our booth at 1434 and take advantage of our innovations that can help you achieve shorter product development cycles, greater efficiency, and better durability.

Read more...
News & Events

Science Brunch – IPERMON

On the 8th of October the climate and energy fund invites Gantner Instruments Vice President Jürgen Sutterlüti to present the project IPERMON at the science brunch in Vienna.

Read more...
News & Events

TestRig Symposium

The two-day TestRig symposium presents the current state of the art, future-oriented developments and outstanding case studies in the field of test rig construction and operation, and promotes the personal exchange of experience. The symposium will be complemented by an accompanying exhibition.

Read more...