|  | e.gate, versions IP, DP, EC Data Concentrator |  | | |  |  | | e.gate | |  | | | |  | Above a certain number of measurement or I/O modules it might be useful to increase the capability and the data rate with one or several e.gates. e.g. up to 120.000 values per second will be posssible via Profibus-DP |  | Ethernet interface, Profibus-DP (DP-version) and EtherCAT (EC-version) Time synchronous access to synchronized and asynchronized data |  | High rate of data acquisition and transmission Each e.gate up to 48000 real values per second, input/output data |  | Acquisition of a high number of channels Ethernet: 1024 Byte, max. 304 integer or 192 real values
Profibus-DP: 244 Byte, max. 120 integer or 60 real values
EtherCAT: According specification ETG |  | Data buffer 16 Mbyte Data buffer for block transfer of measurement data (FTP/socket) |  | 8 digital I/O's Alarm, synchronisation, watchdog, trigger |  | Open data structure Complete integration into automation systems possible |  | | | |  |  |  | |  | e.pac, vers. IP, DP, EC, DL Programmable Automation Controller |  | | |  |  | | e.pac | |  | | | |  | With the e.pac any functionality can be defined with several quantities, I/O's, calculations, timing elements, controllers, and these can be stored to the e.pac measurement system. After loading the function into the e.pac it will run autarkic without PC. |  | Extensive library of function blocks Sequencing blocks, data archives, controller and further transmissionblocks, mathematics, numerics, Boolean combinations, function generators, digital filter (high, low, pass) |  | Data memory 16 MByte, DL version 128 MByte flash Configurable memory for measuremets, I/Os and variables. Trigger function and rate selectable at each archive |  | Synchronized mode Synchronization of the data acquisition, the data transfer and the PAC functionality with 1 kHz |  | Ethernet interface and Profibus-DP (DP-version), EtherCAT (EC-version) and USB (DL-version) Time synchronous access to synchronized and asynchronized data |  | Open data structure Complete integration into automation systems possible |  | | | |  |  |  | |  | e.xact, version IP, DP Multi Functional Test Controller |  | | |  |  | | e.xact | |  | | | |  | The Test Controller e.xact features dynamic and presice measurements, fast conditioning and for analog output as well as digital data transmission via standard interfaces - incl. PAC functionality |  | 4 x multifunctional anlog inputs Input channels for voltage, current and bridges, sample rate 10 kHz each channel |  | 4 x analog outputs Refresh rate 10 kHz each channel |  | Data memory 16 MByte Configurable memory for measuremets, I/Os and variables. Trigger function and rate selectable at each archive |  | Graphically programmable PAC functionality Easy application set-up per configuration plus programmable by e.con |  | Ethernet interface and Profibus-DP (DP-version) Time synchronous access to synchronized and asynchronized data |  | | | |  |  |  | |  | e.reader Intelligent Data Logger |  | | |  |  | | e.reader | |  | | | |  | 8 analog inputs Voltage, current and resistance measurement, Pt100, Pt1000, supply of external sensors |  | Analog-/digital conversion Resolution 19 bit, sample rate 1 s up to 24 h |  | 6 digital in-/outputs and 2 relay outputs Status, counter, frequency measurement |  | Data memory with individual logging interval 128 MB flash, 16 MB RAM, 1 s up to 24 h individual per channel |  | Low power consumption in power safe mode 50 mW / 200 mW at a sample rate of 10 min / 10 s |  | Several communication possibilities RS485, RS232, Ethernet TCP/IP, Modem: FTP via PPP, GPRS via Tunnel, FTP client and FTP server, e-mail generator with data attachment |  | PAC functionality Sequences, calculations, combinations, evaluations, decisions |  | | | |  |  |  |
|
 |
|
 |
|
|
|