|  | e.rack A1-16 slimline General Purpose Measurin Unit |  | | |  |  | | Plug in Unit | |  | | | |  | 16 general prupose analog input channels Voltage, current, resistance, thermocouple, Pt100, Pt1000, bridges |  | High resolution fast A/D conversion 19 bit resolution at 1000 samples/s per channel |  | Signal conditioning Linearization, digital filtering, averaging, minimum/maximum storage, arithmetic, alarm |  | RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |  | | | |  |  |  | |  | e.rack A3-16 slimline Multi-Channel Voltage Unit |  | | |  |  | | Plug in Unit | |  | | | |  | 16 analog input channels Difference voltage |  | High resolution 19 bit resolution at 100 samples/s per channel (total 1600/s) |  | Signal conditioning Linearization, digital filtering, averaging, minimum/maximum storage, arithmetic, alarm |  | RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |  | | | |  |  |  | |  | e.rack A4-16 slimline Multi-Channel Thermocouple and Voltage Unit |  | | |  |  | | Plug in Unit | |  | | | |  | 16 analog, high speed, galvanic isolated channels Thermocouple, 19 bit at 100 samples/s |  | Cold junction compensation Integrated CJC each input |  | Dynamic linearization Optimised linearization for the types B, E, J, K, L, N, R, S, T, U |  | Signal conditioning Linearization, digital filtering, averaging, minimum/maximum storage, arithmetic, alarm |  | RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |  | | | |  |  |  | |  | e.rack A5-16 slimline Multi-Channel RTD (Pt100/Pt1000) and Resistance Unit |  | | |  |  | | Plug in Unit | |  | | | |  | 16 analog input channels Pt100, Pt1000 and resistance |  | Excellent temperature stability e.g. Pt100: 0.05 °C at -20 to +60 °C environment temperature of the e.rack slimline |  | Signal conditioning Linearization, digital filtering, averaging, minimum/maximum storage, arithmetic, alarm |  | RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |  | | | |  |  |  | |  | e.rack A6-16 slimline Carrier Frequency Bridge Unit |  | | |  |  | | Plug in Unit | |  | | | |  | 16 universal bridge inputs Strain gauge full and half bridges, inductive bridges, LVDT |  | High resolution fast A/D conversion 19 bit resolution at 500 samples/s per channel |  | 1 analog output per channel +/- 10 V/100 Hz, each variable signal selectable, e.g. maximum or envelope curve |  | Signal conditioning Linearization, digital filtering, averaging, minimum/maximum storage, envelope curve, arithmetic, alarm |  | RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |  | | | |  |  |  | |  | e.rack D1-64 slimline General Purpose Digital Unit |  | | |  |  | | Plug in Unit | |  | | | |  | 64 configurable digital inputs/outputs Status I/O, process or host controlled |  | Up to 32 frequency inputs Chronos method (simultaneous edge counting and cycle time measurement) up to 2 MHz |  | Up to 32 counter inputs Quadrature counter, up/down counter, up to 400 kHz |  | RS 485 fieldbus interface Profibus-DP, Modbus RTU, ASCII |  | | | |  |  |  | |  | e.rack system structure 3 rack units / desk housing |  | | |  |  | | e.rack with Touch Screen Display | |  | | | |  | Compact measuring system for all common measurement and I/O signals prepared for 10 plug-in units for connection of analog and digital signals |  | Data Concentrator e.gate R Optimization at high number of channels and high data rate, 16 MByte data memory |  | Programmable Automation Controller e.pac R Complex functionality such as PID controller, state machine, arithmetic, numeric and logical operations, 16 MByte data memory |  | Touch Screen Display Monochrome 3.8", 1/4 VGA (320 x 240), LED illuminated |  | AC or DC supply, connections 10 ... 30 VDC or 115/230 VAC, sensor and I/O connectors front or rear panel |  | | | |  |  |  | |  | e.rack A1 General Purpose Measuring Plug-In |  | | |  |  | | Measuring Plug-Ins | |  | | | |  | 2 general purpose analog input channels voltage, current, resistance, Pt100, Pt1000, thermocouples, bridges |  | High accuracy and dynamic Accuracy 0.01%, ADC resolution and calculation accuracy of 19 bit, measuring rate up to 1000 samples/sec |  | Signal conditioning Linearization, digital filtering, averaging, scaling, minimum/maximum store, arithmeric, alarm |  | 1 solid state relay output per channel Status, alarm, limit value, tolerance band |  | Galvanic isolation of I/O-signals, power supply and communication interface |  | | | |  |  |  | |  | e.rack A3 Multi-Channel Voltage Plug-In |  | | |  |  | | Measuring Plug-Ins | |  | | | |  | 8 analog input channels Differential voltage, ranges +/- 10V, +/- 2 V |  | High accuracy at high density Accuracy 0.01%, ADC resolution 19 bit, Measuring rate 100samples/sec per measuring channel, total rate 800 samples/sec |  | Signal conditioning Digital filtering, averaging, scaling, minimum/maximum store, arithmetic, alarm |  | 2 digital inputs and outputs Status, tare, reset |  | Galvanic isolation of I/O-signals, power supply and communication interface |  | | | |  |  |  | |  | e.rack A4 Multi-channel Thermocouples and Voltage Plug-In |  | | |  |  | | Measuring Plug-Ins | |  | | | |  | 8 analog, high speed, galvanic isolated channels Thermocouple and Voltage +/- 80mV |  | High accuracy at high density Accuracy 0.01%, ADC resolution 19 bit, Measuring rate 100samples/sec per measuring channel, total rate 800 samples/sec |  | Cold junction compensation CJC per terminal strip (special terminal block required) |  | Dynamic linearization Optimised linearization for the types B, E, J, K, L, N, R, S, T, U |  | Signal conditioning Digital filtering, averaging, scaling, minimum/maximum store, arithmetic, alarm |  | | | |  |  |  | |  | e.rack A5 Multi-channel RTD (Pt100/Pt1000) and Resistance Plug-In |  | | |  |  | | Measuring Plug-Ins | |  | | | |  | 4, 6 or 12 input channels Pt100, Pt1000 and resistance |  | High accuracy and Accuracy 0.05 °C, ADC resolution 19 bit, temperature stability 2.5 ppm/K |  | Signal conditioning Linearization, digital filtering, averaging, scaling, minimum/maximum store, arithmetic, alarm |  | 2 digital inputs and outputs Status, tare, reset |  | Galvanic isolation of I/O-signals, power supply and communication interface |  | | | |  |  |  | |  | e.rack A6 Carrier Frequency Plug-In |  | | |  |  | | Measuring Plug-Ins | |  | | | |  | 2 universal bridge inputs Strain gauge full-, half- and quarter bridges, inductive bridges, LVDT etc. |  | 1 digital input and 1 digital output each channel Definition of the functionality ( e. g. tare, alarm, limit value, tolerance band) |  | Signal conditioning Linearization, digital filter, scaling, taring, minimum/maximum store, envelope curve, arithmetic, alarm, limit value, tolerance band |  | 1 analog output each channel +/- 10V, each variable signal selectable, e. g. maximum or envelope curve |  | Galvanic isolation of I/O-signals, power supply and communication interface |  | | | |  |  |  | |  | e.rack A9 Multi-Channel Analog Output Plug-In |  | | |  |  | | Analog Plug-In | |  | | | |  | 8 analog output channels Voltage +/- 10 V and current 0 to 20 mA selectable |  | High accuracy and resolution Accuracy 0.02%, DAC resolution 16 bit at a sample rate of 1000 samples/sec |  | Signal conditioning Scaling, minimum/maximum store, arithmetic, alarm |  | 2 digital outputs Status, alarm, limit value, tolerance band |  | Galvanic isolation of I/O-signals, power supply and communication interface |  | | | |  |  |  | |  | e.rack D1 Multi-channel Digital Plug-In |  | | |  | | | | |