|  | e.bloxx A1 Universal module for all standard measurement and signal inputs |  | | |  |  | | e.bloxx A1-1 | |  | | | |  | 1, 4 or 8 universal input channels Voltage, current, resistance, Pt100, Pt1000, thermocouples, meaurement bridges |  | 1 digital input per channel Status, reset |  | 1 solid state relay output per channel Status, alarm, threshold, tolerance band |  | ADC-conversion and signal conditioning with 19 bit up to 1000/s Linearization, digital filter, average, scaling, min/max memory, arithmetics |  | RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |  | | | |  |  |  | |  | e.bloxx A2 Fast general purpose measuring module for ICP and strain gauge sensors |  | | |  |  | | e.bloxx A2-1 | |  | | | |  | 1 general purpose analog input channel strain gauge, piezo resistive bridges, and ICP sensors, voltage, current |  | 1 digital input and 1 digital output Status, zero balance, memory reset, alarm, limit value, tolerance band |  | Signal conditioning Linearization, digital filtering, averaging, scaling, minimum/maximum store, true RMS value, arithmetic |  | TEDS functionality Reading of Transducer Electronic Data Sheet from a TEDS sensor module and setup of the A2 internals automatically (IEEE 1451.4 Class 2) |  | RS 485 fieldbus interface Modbus-RTU, ASCII, and Local Bus to Test Controller |  | | | |  |  |  | |  | e.bloxx A3 Multi channel module for voltage and current, attractive channel price |  | | |  |  | | e.bloxx A3-1 | |  | | | |  | 4 or 16 galvanic isolated voltage / current input channels Differential voltage, current (with e.bloxx Terminal 4C), galvanically isolated 100VDC |  | Sample rate 100/s with 4 active channels Module sample rate 400/s |  | 1 digital input and 1 digital output Status, reset, alarm, threshold, tolerance band |  | ADC-conversion and signal conditioning with 19 bit Linearization, digital filter, average, scaling, min/max memory, arithmetics |  | RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |  | | | |  |  |  | |  | e.bloxx A4TC Multi channel module for thermocouple and voltage, attractive channel price |  | | |  |  | | e.bloxx A4-1TC | |  | | | |  | 4 or 16 galvanic isolated Thermocouple input channels Thermocouples, voltages +/- 80 mV |  | Dynamic linearization Optimized use of base points for type B, E, J, K, L, N, R, S, T, U, import of individual curves |  | ADC-conversion and signal conditioning with 19 bit and up to 100/s Linearization, digital filter, average, scaling, min/max memory, arithmetics |  | RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |  | | | |  |  |  | |  | e.bloxx A5 Precise module for Pt100/Pt1000 |  | | |  |  | | e.bloxx A5-1 | |  | | | |  | RTD input module Pt100/Pt1000, resistance in 2, 3 or 4 wire |  | 1 digital input Status, reset |  | 1 digital output Alarm, threshold, tolerance band |  | ADC-conversion and signal conditioning with 19 bit Linearization, digital filter, average, scaling, min/max memory, arithmetics |  | RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |  | | | |  |  |  | |  | e.bloxx A5CR 2-channel module for Cryo application |  | | |  |  | | e.bloxx A5-1CR | |  | | | |  | 2 Input channels for Cryo sensors e.g. Type Cernox or TVO |  | Sensor excitation 8 µAeff only to avoid self heading of the sensor |  | Individual linearization of the sensor characteristics Sensor specific linearization by using 64 nodes and archive in a sensor data file (import function). |  | 1 digital input, 1 digital output Status, alarm, limit value, tolerance band |  | RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |  | | | |  |  |  | |  | e.bloxx A6-2CF Carrier Frequency Bridge Module |  | | |  |  | | e.bloxx A6-2CF | |  | | | |  | Universal carrier frequency sensor connection Strain gauges full, half and quarter bridges, inductive bridges, LVDT |  | 6 digital inputs and 4 digital outputs Functions definable, e.g. memory delete, frequency measurement, counter, alarm, threshold, tolerance band, status |  | 2 analog outputs +/- 10 V, any variable attributable, e.g. netto and envelope curve |  | ADC-conversion and signal conditioning with 19 bit and 5000/s Linearization, digital filter 4th pole, scaling, tare, min/max memory, run/hold, envelope curve, arithmetics, alarm, threshold, tolerance band |  | RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |  | | | |  |  |  | |  | e.bloxx A9 Analog output module |  | | |  |  | | e.bloxx A9-1 | |  | | | |  | 4 analog outputs Voltage +/- 10V and current 4..20mA selectable |  | 16 bit DAC Conversion rate up to 1000/s |  | 1 digital input and 1 digital output Status, tara, reset, alarm, threshold, tolerance band |  | Signal conditioning Scaling, min/max memory, arithmetics |  | RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |  | | | |  |  |  | |  | e.bloxx D1 Digital module |  | | |  |  | | e.bloxx D1-1 | |  | | | |  | 8 to 32 digital in/outputs freely configurable |  | Status in-/output Process or host controlled |  | Frequence in-/output Chronos method for precise and fast frequence measurement up to 2 MHz, frequency and PWM output |  | Counter input Quadrature counter, Up/Down counter up to 400 kHz |  | RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |  | | | |  |  |  | |  | e.bloxx D2 Relay module |  | | |  |  | | e.bloxx D2-1 | |  | | | |  | 4 relay outputs 2 closing contacts and 2 switchable contacts |  | Switching of electrical power 230 VAC / 3 A, 30 VDC / 3 A |  | Many operations Expected mechanical life-span: 50,000,000 cycles |  | RS485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII |  | | | |  |  |  | |  | e.bloxx D3 Multipurpose CAN and serial interface module |  | | |  |  | | e.bloxx D3 | |  | | | |  | e.bloxx D3-CAN - CAN input and output CAN node 2.0A / 2.0B ref. to ISO 11898 |  | e.bloxx D3-COM - RS-485 und RS-232 Master For connecting of serial devices and fieldbus slaves,
standard protocol Modbus-RTU, others on request |  | e.bloxx D3-SSI - RS-422 Master For connection absolute encoders (e.g. angle, displacement)
with SSI (serial synchrony interface) |  | 6 digital inputs and 4 digital outputs Definition of functions like status, alarm or counter |  | RS-485 fieldbus (slave) interface Profibus-DP, Modbus-RTU, ASCII |  | | | |  |  |  |
|
 |
|
 |
|
|
|