Measurement and Test Automation
deutsch

Signal Conditioning:
The Controller Level

Test-Controller

The addition of a Test Controller transforms the Q.bloxx modules into a powerful test automation and control system.

The Test Controller is the interface between the Q.bloxx modules and the respective automation system, handling all of the synchronization, data buffering, control, and transfer of data to the automation system (typically on a PC). Different application requirements (number of points, maximum throughput rates, programming and control requirements, etc.) will dictate which Test Controller is best suited.The Test Controllers connect via Ethernet TCP/IP for configuration of the entire measurement system (including the Q.bloxxs), and for basic data acquisition and transfer tasks. 

 Q.gateQ.pac
 HOST-INTERFACES ↓  
Ethernet TCP/IP
EtherCAT Q.pac EC only
Profibus-DPQ.gate DP only 
USB Host/Device
RS-232
RS-485 
 SLAVE-INTERFACES ↓  
RS-48524
 DATA STORAGE ↓  
16 MB RAM
128 MB RAM Flash 
USB expandable
 MIN.CYCLETIME1 ms0,1 ms
 REALTIME CLOCK 
 DIGITAL I/OsQ.gate DP only: 4x fix8x fix
Syncronization possible
Trigger I/Os 
 FREE PROGRAMMABILITY PAC-FUNCTION
E-Mail over Ethernet
FTP-Client over Ethernet
 POWER CONSUMPTION TYPICAL (W)Q.gate IP: 2,5
Q.gate DP: 3,0
4,5
 Q.gateQ.pac
 

Q.gate IP / DP

  • Connection of up to 32 Q.bloxx modules
  • via 2 UARTS, Baud rate up to 24 MBaud each UART
  • Recording of up to 256 variables
  • real format 4 Byte
  • Synchronization and time stamp of measurement values
  • Ethernet interface for configuration and data output
  • FTP, TCP/IP, UDP
  • FTP Server and FTP Client functionality
  • configurable function
  • Optional fieldbus interface
  • Profibus-DP, 12 Mbps
  • High data rate over Ethernet
  • 128 real variables with 1 kHz (block transfer)
    16 real variables with 10 kHz (block transfer)
    64 real variables with 300 Hz (online)
  • Data buffer memory 12 MByte
  • Data buffer at block transfer of measurements
  • Mathematic, control and combination features
  • PAC functionality with extensive function block library
  • Sequences, data logger, PID-controller, transfer functions, mathematic, numeric, Boolean combinations, functions generator
  • Galvanic isolation
  • of power supply and interfaces
  • Electromagnetic Compatibility
  • according EN 61000-4 and EN 55011
  • Power supply 10…30 VDC
  • DIN rail mounting (EN 50022)
up to table ↑

 
 

Q.pac DL / EC

  • Connection of up to 32 Q.bloxx modules
  • via 4 UARTS, Baud rate up to 24 MBaud each UART
  • Recording of up to 256 variables
  • real Format 4 Byte
  • Synchronization and time stamp of measurement values
  • Ethernet interface for configuration and data output
  • FTP, TCP/IP, UDP
  • FTP Server and FTP Client functionality
  • configurable function
  • Optional fieldbus interface
  • EtherCAT according specification ETG
  • High data rate over Ethernet
  • 128 real variables with 1 kHz (block transfer)
    16 real variables with 10 kHz (block transfer)
    64 real variables with 300 Hz (online)
  • Data buffer memory dyn. 12 MByte, stat. 128 MByte
  • Data buffer at block transfer of measurements
  • PAC functionality with extensive function block library
  • Sequences, data logger, PID-controller, transfer functions, mathematic, numeric, Boolean combinations, functions generator
  • Galvanic isolation
  • of power supply and interfaces
  • Electromagnetic Compatibility
  • according EN 61000-4 and EN 55011
  • Power supply 10…30 VDC
  • DIN rail mounting (EN 50022)
up to table ↑

 
 
© 2010 Gantner Instruments: Intelligent Solutions for Measurement and Test Automation - Imprint
--
© Gantner Instruments Test & Measurement GmbH, Industriestr. 12, 64297 Darmstadt, Phone: +49 6151 95136-0, Fax: +49 6151 95136-26 - The preparation of all the contents and details included on Internet pages is undertaken without accepting liability for the completeness and correctness of this information. - Page: http://www.gantner-instruments.com/distributed-systems/q-series/controller, September 9, 2010