| | INPUT TYPES ↓ | A1 | A3 | A4TC | A5 | A5CR | A6-2CF | A9 | D1 | D2 | D3 |
|---|
 | Voltage |  |  |  | | | | | | | |
|---|
 | Current |  |  | | | | | | | | |
|---|
 | Resistance |  | | |  | | | | | | |
|---|
 | Pt100, Pt1000 |  | | |  | | | | | | |
|---|
 | Potentiometer |  | | | | | | | | | |
|---|
 | Thermocouple |  | |  | | | | | | | |
|---|
 | Cryo Sensor | | | | |  | | | | | |
|---|
 | Single Strain Gauge | | | | | |  | | | | |
|---|
 | Half Bridge Strain Gauge | | | | | |  | | | | |
|---|
 | Full Bridge Strain Gauge |  | | | | |  | | | | |
|---|
 | Inductive Half Bridge | | | | | |  | | | | |
|---|
 | Inductive Full Bridge | | | | | |  | | | | |
|---|
 | LVDT | | | | | |  | | | | |
|---|
 | ICP Sensor | | | | | | | | | | |
|---|
 | Frequency Signal | | | | | |  | |  | | |
|---|
 | Pulse Width | | | | | | | |  | | |
|---|
 | Counter | | | | | |  | |  | | |
|---|
 | Status |  |  | |  |  |  |  |  | |  |
|---|
 | CAN Data | | | | | | | | | |  |
|---|
 | Serial Sensors, SSI | | | | | | | | | |  |
|---|
| | OUTPUT SIGNAL ↓ | A1 | A3 | A4TC | A5 | A5CR | A6-2CF | A9 | D1 | D2 | D3 |
|---|
 | Voltage | | | | | |  |  | | | |
|---|
 | Current | | | | | | |  | | | |
|---|
 | Frequency | | | | | | | |  | | |
|---|
 | Pulse Width | | | | | | | |  | | |
|---|
 | Status |  |  | |  |  |  |  |  | |  |
|---|
 | Relays | | | | | | | | |  | |
|---|
 | CAN Data | | | | | | | | | |  |
|---|
 | Serial Actuator | | | | | | | | | |  |
|---|
| | NUMBER OF CHANNELS | 1 (4) | 4 (16) | 4 (16) | 2/3/6 | 2 | 1 | 4 | 8 (32) | 4 | 16 |
|---|
| | DATA RATES MAX. PER CHANNEL PER SECOND | 1000 | 100 | 100 | 10 | 1 | 1000 | 1000 | 1000 | 100 | 1000 |
|---|
| | Details ↓ | A1 | A3 | A4TC | A5 | A5CR | A6-2CF | A9 | D1 | D2 | D3 |
|---|
Hint: In case you can not see the complete table use the F11 key to switch to full screen mode.
e.bloxx Module A1
- 1 or 4 universal input channels
- Voltage, current, resistance, Pt100, Pt1000, thermocouples, meaurement bridges
- 1 digital input per channel
- Status, reset
- 1 solid state relay output per channel
- Status, alarm, threshold, tolerance band
- ADC-conversion and signal conditioning with 19 bit up to 1000/s
- Linearization, digital filter, average, scaling, min/max memory, arithmetics
- RS 485 fieldbus interface
- Profibus-DP, Modbus-RTU, ASCII
up to table ↑ e.bloxx Module A3
- 4 or 16 galvanic isolated voltage / current input channels
- Differential voltage, current (with e.bloxx Terminal 4C), galvanically isolated 100VDC
- Sample rate 100/s with 4 active channels
- Module sample rate 400/s
- 1 digital input and 1 digital output
- Status, reset, alarm, threshold, tolerance band
- ADC-conversion and signal conditioning with 19 bit
- Linearization, digital filter, average, scaling, min/max memory, arithmetics
- RS485 fieldbus interface
- Profibus-DP, Modbus-RTU, ASCII
up to table ↑ e.bloxx Module A4TC
- 4 or 16 galvanic isolated Thermocouple input channels
- Thermocouples, voltages ±80 mV
- Dynamic linearization
- Optimized use of base points for type B, E, J, K, L, N, R, S, T, U, import of individual curves
- ADC-conversion and signal conditioning with 19 bit and up to 100/s
- Linearization, digital filter, average, scaling, min/max memory, arithmetics
- RS485 fieldbus interface
- Profibus-DP, Modbus-RTU, ASCII
up to table ↑ e.bloxx Module A5
- RTD input module
- Pt100/Pt1000, resistance in 2, 3 or 4 wire
- 1 digital input
- Status, reset
- 1 digital output
- Alarm, threshold, tolerance band
- ADC-conversion and signal conditioning with 19 bit
- Linearization, digital filter, average, scaling, min/max memory, arithmetics
- RS485 fieldbus interface
- Profibus-DP, Modbus-RTU, ASCII
up to table ↑ e.bloxx Module A5CR
- 2 Input channels for Cryo sensors
- e.g. Type Cernox or TVO
- Sensor excitation 8 µAeff only
- to avoid self heading of the sensor
- Individual linearization of the sensor characteristics
- Sensor specific linearization by using 64 nodes and archive in a sensor data file (import function).
- 1 digital input, 1 digital output
- Status, alarm, limit value, tolerance band
- RS 485 fieldbus interface
- Profibus-DP, Modbus-RTU, ASCII
up to table ↑ e.bloxx Module A6-2CF
- Universal carrier frequency sensor connection
- Strain gauges full, half and quarter bridges, inductive bridges, LVDT
- 6 digital inputs and 4 digital outputs
- Functions definable, e.g. memory delete, frequency measurement, counter, alarm, threshold, tolerance band, status
- 2 analog outputs
- ±10 V, any variable attributable, e.g. netto and envelope curve
- ADC-conversion and signal conditioning with 19 bit and 5000/s
- Linearization, digital filter 4th pole, scaling, tare, min/max memory, run/hold, envelope curve, arithmetics, alarm, threshold, tolerance band
- RS485 fieldbus interface
- Profibus-DP, Modbus-RTU, ASCII
up to table ↑ e.bloxx Module A9
- 4 analog outputs
- Voltage ±10 V and current 4..20 mA selectable
- 16 bit DAC
- Conversion rate up to 1000/s
- 1 digital input and 1 digital output
- Status, tara, reset, alarm, threshold, tolerance band
- Signal conditioning
- Scaling, min/max memory, arithmetics
- RS485 fieldbus interface
- Profibus-DP, Modbus-RTU, ASCII
up to table ↑ e.bloxx Module D1
- 8 to 32 digital in/outputs
- freely configurable
- Status in-/output
- Process or host controlled
- Frequence in-/output
- Chronos method for precise and fast frequence measurement up to 2 MHz, frequency and PWM output
- Counter input
- Quadrature counter, Up/Down counter up to 400 kHz
- RS485 fieldbus interface
- Profibus-DP, Modbus-RTU, ASCII
up to table ↑ e.bloxx Module D2
- 4 relay outputs
- 2 closing contacts and 2 switchable contacts
- Switching of electrical power
- 230 VAC / 3 A, 30 VDC / 3 A
- Many operations
- Expected mechanical life-span: 50,000,000 cycles
- RS485 fieldbus interface
- Profibus-DP, Modbus-RTU, ASCII
up to table ↑ e.bloxx Module D3
- e.bloxx D3-CAN - CAN input and output
- CAN node 2.0A / 2.0B ref. to ISO 11898
- e.bloxx D3-COM - RS-485 und RS-232 Master
- For connecting of serial devices and fieldbus slaves, standard protocol Modbus-RTU, others on request
- e.bloxx D3-SSI - RS-422 Master
- For connection absolute encoders (e.g. angle, displacement) with SSI (serial synchrony interface)
- 6 digital inputs and 4 digital outputs
- Definition of functions like status, alarm or counter
- RS-485 fieldbus (slave) interface
- Profibus-DP, Modbus-RTU, ASCII